Sign In | Join Free | My lightneasy.org |
|
Brand Name : Sino-NSH
Model Number : VFD-200
Certification : CE ISO,ISO9001,SGS,CE/ ISO,BV
Place of Origin : China
MOQ : 1 set
Price : USD 5000-20000 dollar
Payment Terms : L/C, T/T, Western Union, MoneyGram
Supply Ability : 50 sets per month
Delivery Time : 15-25 working days for OEM
Packaging Details : Strong wooden cases, suitable for long distance sea freight transportation and changing climate, good resistance to moisture and shocks
Voltage : 380v/50hz and as your option
Power(w) : 40-135Kw
Condition : New
Weight : 685-1900KG
Dimension(l*w*h) : according to Machine
After-sales service provided : Engineers available to service machinery overseas
Flow : 1800 L/h-18000L/h
Working pressure : Lower than 0.5 Mpa
Usage : Transformer Oil,Lubricant Oil,Insulation Oil,Industrial Oil Filtrator
Warranty : 1 Year
Function : Transformer oil purification,Degases and removes the impurities,Degassing,Dewaters
Color : Customizable
Breakdown voltage : ≥75KV
Type : Vacuum Oil Purifier,Double Stage Vacuum Insulating Oil Regeneration System,High Eficiency,Portable Filtration
Working temperature : 45 ~ 65
Name : Double Stage Vacuum Transformer Oil Filtration Plant 3000 L/H Oil Treatment Machine
Capacity : 30-300L/Min,As user need
Heating power : 30~192Kw
12000L/H Transformer Oil Purifier NSH VFD Series Double Stage Vacuum Oil Treatment System
General
The NSH VFD Series is engineered to improve the quality of transformer insulating oils. This series is highly effective in removing trace water, gases, and particulate contaminants from insulation oils, ensuring the optimal performance of transformers, circuit breakers, inductors, cables, and capacitors with insulation systems. The VFD series excels in purifying branded oils and insulation oils used in high-voltage and ultra-high-voltage transformers. Moreover, it is ideal for processing low-viscosity lubricating oils, delivering superior purification efficiency.
Operating conditions:
The installation shall be designed to opeartae satifactory at ambient temperatures ranging from -20 deg.C to 55 deg. C
Description
The NSH VFD Series utilizes cutting-edge coacervation, coalescence, separation, and advanced purification technologies. This powerful combination allows for the efficient and quick removal of free and dissolved water, carbon particles, dissolved gases, and contaminants from insulating oil, ensuring peak performance and long-term reliability.
Edges
Main components
a.Pre-filter:
Utilizes a 50-80mesh strainer to remove any large particles
b. Electric heater:
Oil Heater System assures less than 1.0 w/cm². During the heating process, the deterioration of the oil caused by overheating is avoided. The oil temperature can be adjusted between 20℃ to 80℃.The heater is controlled manually or automatically. The heater will stop automatically when the oil temperature reaches a certain degree. Being installed with safety protection devices, the heating system is secure and reliable. The heater will stop operation automatically when the oil volume of inlet is too low to avoid the damages of the heater.
c. Vacuum chamber:
Utilizes coacervation technology, coalescing technology, separating technology and refined purification technology. To remove free, soluble water, free and dissolved gases. The oil-level floating ball or infrared liquid level automatic controller system are installed in the vacuum vessel to control the oil level so as to avoid the oil being
suctioned into vacuum pump in the operation. The new innovation of eliminating froth can avoid the oil being suctioned into vacuum pump.
d. Oil cooler:
Connected to between vacuum chamber and the roots pump, the vacuum pump to avoid oil entering roots pump and vacuum pump. Secondly, to cool the heated air.
e. Oil discharge pump:
Featuring high suction capabilities removes oil from the processing chamber and discharges the oil through a filter before it is directed either through the discharge port or is re-circulated within the system.
f. Fine filter:
Oil receives its final “polishing” treatment by passing through a high performance element. The filter is rated to capture99.5% of particles greater from 5 to 10 micron absolute.
g. Sampling probe:
Two (2) sampling probes shall be provided, one for the incoming oil and one for the processed oil.
h. Inlet&discharge valves:
Manual valves are provided for the inlet and discharge connection.
i. Manual re-circulation valve:
One manual valve is provided for re-circulation purposes.
j. Transformer dry-out connection:
One transformer dry-out connection.
k. Control panel:
Instrumentation, alarms& interlocks instrumentation&electrical controls are located in NEMA 12 type enclosure. Several pilot lights are provided to indicate operational status(on/off) of key components and alarm conditions.
Technical Specifications:
Item | Unit | VFD-30 | VFD-50 | VFD-100 | VFD-150 | VFD-200 | VFD-300 | ||
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 18000 | ||
Vacuum Range | MPa | -0.092~~-0.099 | |||||||
Max Vacuum Range | Pa | ≤ 50 | |||||||
Working Pressure | MPa | ≤ 0.2 | |||||||
Temperature Range | ℃ | 45-65 | |||||||
Water Content | PPm | ≤ 4 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Breakdown Voltage | Kv | 75 | |||||||
Power Supply | V | ~50Hz 380V(or as needed) | |||||||
Working Noise | dB | ≤ 72 | ≤ 78 | ||||||
Heating Power | Kw | 30 | 48 | 90 | 120 | 180 | 240 | ||
Total Power | Kw | 33 | 52 | 95 | 126 | 186 | 248 | ||
Inlet(Outlet)Diameter | Mm | DN25 | DN32 | DN40 | DN50 | DN65 | DN65 | ||
Net Weight | Kg | 350 | 480 | 750 | 1100 | 1250 | 1420 | ||
Size | length | Mm | 1500 | 1500 | 1900 | 2100 | 2400 | 2600 | |
width | Mm | 1100 | 1250 | 1400 | 1600 | 1700 | 1800 | ||
height | Mm | 1750 | 1750 | 1800 | 1900 | 1900 | 2000 |
![]() |
12000L/H Transformer Oil Purifier NSH VFD Series Double Stage Vacuum Oil Treatment System Images |